| Model | QX43 S1 |
QX43 S2 |
QX43 P1 |
QX43 P2 |
QX43 D1 |
QX43 D2 |
QX43 D3 |
QX43 D4 |
QX43 D5 |
Wavelength (nm) |
310/1550 ±20 |
1310/1550| ±20 |
1310/1550/ 1625±20 |
1310/1550/ 1650±20 |
1550 |
1610 | 1577 | 1625 |
1650 |
| Dynamic range (dB) | 26/24 | 31/29 | 26/24/24 | 26/24/24 | 24 | 24 | 24 | 24 | 25 |
| Event blind
spot (m)★① |
≤1.5 | ||||||||
| Attenuation blind
zone (m)★② |
≤5 | ||||||||
| Number of fiber
interfaces |
1 FC/UPC | 2 FC/UPC | 1 FC/UPC | ||||||
| Applicable
optical fiber |
SM | SM-Live | SM | ||||||
| Range(km) | 0,5,1,2,5,10,20,35,50,75,100,150 | ||||||||
| Distance accuracy(m) | ± (1m + measurement distance × 2 × 10 − 5 + collection point resolution) |
||||||||
| Pulse width(ns) | 5,10,20,50,100,200,500,1000,2000,10000,20000 | ||||||||
| Number of sampling points | ≥15000 | ||||||||
| Sampling resolution(m) | 0.04 | ||||||||
| Loss accuracy | 0.03dB/dB | ||||||||
| Reflection accuracy | ±2dB | ||||||||
| Optical power meter module (built-in function) | √ | |
| OPM | Measurement wavelength range | 800~1650nm |
| Correction wavelength(nm) | 850,1300,1310,1490,1550,1625,1650 | |
| Measurement power range | -70~6dBm | |
| Measurement accuracy | <(±0.2dB or ±5%) | |
| Display resolution | 0.01dB | |
| Power meter interface | FC/UPC+2.5mm Universal Connector | |
| Stable Light Source Module (Built-in Function) |
√ | ||||||
| Wavelength(nm) | 1310/1550 | 1550 | 1610 | 1577 | 1625 | 1650 | |
| SLS | Output power |
≥-10dBm | |||||
| Modulation frequency | CW,270Hz,1kHz,2kHz | ||||||
| Laser safety rating |
Class 1M or Class 1 | ||||||
| Built-in optical fiber interface |
OTDR optical port | ||||||
| Red light source module (built-in function) | √ | |
| VFL | Wavelength(nm) | 650 |
| Output power |
10mW | |
| Modulation mode |
cW,CHOP(2Hz) | |
| Laser safety rating |
Class 3R | |
| Optical fiber interface |
2.5 mm universal connector for FC, SC, ST |
|
| Network test module (built-infunction) |
√ | |
| RJ45 | Applicable network cable |
CAT5,CAT6 |
| Alignment length |
300m | |
| Maximum audio
transmission distance |
300m | |
| General parameters |
|
| Link diagram | √ |
| Pass/Fail display |
X |
| Distance unit |
km |
| PC side analysis software |
√ |
| Language |
English, Chinese, Spanish, French, Portuguese, Russian, Thai, Korean |
| Optical fiber interface |
FC/UPC(SC/UPC optional) |
| Display screen |
4.3-inch color LCD screen (resolution: 800x480) |
| Interface |
Type-c充电接口×1,USB 2.0×1,RJ45×1 |
| Operating temperature |
-10-50 ℃ (0-40 ℃ connected to power supply, 0 to 35 ℃ battery charge) |
| Storage temperature |
-20 to 60℃ |
| Elevation |
4000 m |
| humidity |
0 to 90% RH (at: 20%-90% 739874 AC adapter, no frost)100-240V AC, 50/60 Hz (AC adapter) |
| Power supply mode |
100-240V AC, 50/60 Hz (AC adapter) |
| Battery |
3.7V,6000mAh,≥22Wh |
| Illumination lamp |
Light intensity ≥ 15000 mcd |
| Working hours★③ | 5 hours |
| Data Storage |
Memory: ≥ 1000 test curve; External storage: USB |
| Dimensions |
179 mm(W)×112mm(H)×48 mm(D) |
| Weight |
0.6 kg (mainframe only with battery) |
Notes:
★① Minimum pulse width, return loss: ≥ 55 dB (≥ 40 dB at 850/1300 nm), group refractive index: 1.5, 1.5 dB lower than the unsaturated peak level.
★② Minimum pulse width, group refractive index: 1.5, backscattering level within ± 0. 5 dB of the conventional value. For SMF, 1310 nm wavelength, return loss: ≥ 55 dB. For MMF, 850 nm wavelength, return loss: ≥ 40 dB.
★③ Based on a brand new battery. All data above are based on measurements at 23 °C ± 2 °C (73.4 ° F ± 3.6 ° F).